        DYC-JQµç´ÅÕæ¿Õѹ²î·§
        • DYC-JQµç´ÅÕæ¿Õѹ²î·§
        • DYC-JQµç´ÅÕæ¿Õѹ²î·§
        • DYC-JQµç´ÅÕæ¿Õѹ²î·§
        • DYC-JQµç´ÅÕæ¿Õѹ²î·§

        DYC-JQµç´ÅÕæ¿Õѹ²î·§

        DYC-JQÐ͵ç´ÅÕæ¿Õѹ²î·§ÊÇ»úÐµÕæ¿Õ±Ã°²È«·§£¬°²×°ÓÚ»úÐµÕæ¿Õ±ÃµÄ½øÆø¿Ú£¬²¢Óë±Ãͬ²½¿ªÆôºÍ¹Ø±Õ¡£µ±±ÃÍ£Ö¹¹¤×÷»òµçԴͻȻÖжÏʱ£¬·§ÃÅÀûÓôóÆøÑ¹Á¦Ê¹·§°å×Ô¶¯¹Ø±Õ£¬Ê¹Õæ¿Õϵͳ±£³ÖÕæ¿Õ²¢½«´óÆø³äÈë±ÃÇ»ÄÚ£¬´Ó¶ø±ÜÃâ±ÃÓÍÄæÏòÁ÷¶¯¶øÎÛÈ¾Õæ¿Õϵͳ¡£ÊÊÓýéÖÊΪ´¿¾»¿ÕÆøºÍ·Ç¸¯Ê´ÐÔÆøÌå¡£

        ²úÆ·ÏêÇé

        DYC-JQÐ͵ç´ÅÕæ¿Õѹ²î·§¸ÅÊö

        DYC-JQElectro-vacuum Differential Pressure Valve

        DYC-JQÐ͵ç´ÅÕæ¿Õѹ²î·§ÊÇ»úÐµÕæ¿Õ±Ã°²È«·§£¬°²×°ÓÚ»úÐµÕæ¿Õ±ÃµÄ½øÆø¿Ú£¬²¢Óë±Ãͬ²½¿ªÆôºÍ¹Ø±Õ¡£µ±±ÃÍ£Ö¹¹¤×÷»òµçԴͻȻÖжÏʱ£¬·§ÃÅÀûÓôóÆøÑ¹Á¦Ê¹·§°å×Ô¶¯¹Ø±Õ£¬Ê¹Õæ¿Õϵͳ±£³ÖÕæ¿Õ²¢½«´óÆø³äÈë±ÃÇ»ÄÚ£¬´Ó¶ø±ÜÃâ±ÃÓÍÄæÏòÁ÷¶¯¶øÎÛÈ¾Õæ¿Õϵͳ¡£ÊÊÓýéÖÊΪ´¿¾»¿ÕÆøºÍ·Ç¸¯Ê´ÐÔÆøÌå¡£

        DYC-JQ electro-vacuum differential Pressure valve is a safely valve for mechanical vacuum pump. It is mounted at the intake nozzle of mechanical vacuum pump, synchronously opened and closed with the pump. In case that pump stops working or power supply is suddenly broken off, valve disc will be closed automatically under atmospheric pressure, to keep the vacuum system vacuum and the air charged into pump cavity, thus to prevent pump oil from reverse flow that can pollute the vacuum system. Applicable medium can be pure air or noncorrosive gases.

        DYC-JQÐ͵ç´ÅÕæ¿Õѹ²î·§Ö÷Òª¼¼ÊõÐÔÄÜ

        Main Technical Performance


        ¡¡ÊÊÓ÷¶Î§£ºApplicability ¡¡105¡«10-2Pa
        ¡¡·§ÃÅ©ÂÊ£ºValve Leak Rate ¡¡¡Ü1.3¡Á10-2Pa.L/S.
        ¡¡ÊÊÓÃζȣºApplicable Temperature ¡¡-30¡«+50¡æ
        ¡¡ÏßΧÎÂÉý£ºCoil Temperature Rise ¡¡¡Ü65¡æ
        ¡¡¿ª±Õʱ¼ä£ºOpen-close Time ¡¡¡Ü3S
        ¡¡µçÔ´µçѹ£ºMains Voltage ¡¡220V/50Hz

        Ö÷ÒªÁã¼þ²ÄÁÏ

        Materials of Main Parts


        ·§Ìå¡¢·§¸Ç¡¢·§°å£ºÌ¼¸Ö»òÂÁºÏ½ð
        ¸ôĤ£º¶¡ëæÏ𽺼ӵÓÂÚ³ñ

        Body, bonnet and disc: carbon steel or aluminium alloy
        Diaphragm: NBR and terylene silk

        ÍâÐμ°Á¬½Ó³ß´ç(mm)

        Overall and Connection Dimensions(mm)


        »îÌ×·¨À¼Á¬½Ó(GB6070¡¡Í¼Ò»)

        Model
        ÐͺÅ
        DN Do D D2 n-¦Õc A H
        DYC-JQ50 50 90 110 55 4-¦Õ9 70 203
        DYC-JQ63 63 105 130 68 4-¦Õ9 88 226
        DYC-JQ80 80 125 145 85 8-¦Õ9 98 260
        DYC-JQ100 100 145 165 105 8-¦Õ9 108 282
        DYC-JQ160 160 200 225 165 8-¦Õ12 158 350

        ¿ìж·¨À¼Á¬½Ó(GB4982 ͼ¶þ)

        Model
        ÐͺÅ
        DN D1 D A H B
        DYC-JQ16 16 17.2 30 40 160 55
        DYC-JQ25 25 26.2 40 50 170 60
        DYC-JQ32 32 34.2 55 58 179 60
        DYC-JQ40 40 41.2 55 65 187 70
        DYC-JQ50 50 52.2 75 70 203 85

        ·½ÌåÂÝÎÆÁ¬½Ó(JB919 ͼÈý)

        Model
        ÐͺÅ
        DN Do D2 h B H n-d
        DYC-JQ16 16 42 22 28 48 148 4-M5
        DYC-JQ25 25 55 29 35 58 155 4-M6
        DYC-JQ32 32 64 36 40 68 160 4-M6
        DYC-JQ40 40 70 44 44 80 166 4-M6
        DYC-JQ50 50 90 55 56 94 189 4-M8
        DYC-JQ65 65 105 70 65 115 205 4-M8
        DYC-JQ80 80 125 85 75 140 250 4-M8